This solution has been tested in 50 mm wide joint, with sealant’s depth of 30 mm.
Fire resistance: E180, EI120.
1
Backing the sealant
2
Covering the fibre cord and sealing the joint
To ensure the sealant’s correct thickness, shape and to prevents the joint’s failure, fire-resistant cord must be used to back the sealant.
FireStop FiberFoc 470 – mineral wool fibre cord wrapped in glass fibre.
For long-lasting fire-resistant joints, a special fire-resistant sealant must be used to cover the fibre cord and to seal the joint properly.