PVC pipe penetration fireproofing using mineral wool and acrylic

PVC pipe penetration fireproofing using mineral wool and acrylic

Solution has been tested with PVC pipe Ø 32mm, total penetration width 60 mm and sealant depth 15 mm.

Fire resistance: EI240.

1 2

1

Covering the PVC pipe

2

Sealing the penetrations

Covering the PVC pipe

For fire-resistant covering of PVC pipe in penetration, mineral wool is probably the easiest material to use.

Sealing the penetrations

To ensure fire resistant sealing of pipe penetration before final finishing of the wall, intumescent acrylic must be used.

FireStop Intumescent Acrylic 681 – bright white acrylic-based intumescent sealant for fireproofing joints and sealing penetrations in fire-rated structures. Withstands fire up to 4 hours in a linear and piping joint. Can be painted.